This is a Demo Server. Data inside this system is only for test purpose.
 

Erirms Evaluation of the Reliability of Iot-Aided Remote Monitoring Systems of Low-Voltage Overhead Transmission Lines

dc.authoridKhujamatov, Halimjon/0000-0001-5206-635X
dc.authoridKhayrullaev, Alisher/0009-0005-5060-1079
dc.authoridMukhiddinov, Mukhriddin/0000-0002-1424-0799
dc.authoridDavronbekov, Dilmurod/0000-0003-1193-7918
dc.authoridMirjamol, Abdullayev/0000-0003-1664-7274
dc.authorwosidKhujamatov, Khalimjon/ADF-0611-2022
dc.authorwosidDavronbekov, Dilmurod/ABA-7291-2021
dc.authorwosidAbdullayev, Mirjamol/LMO-4218-2024
dc.authorwosidMukhiddinov, Mukhriddin/S-3112-2018
dc.contributor.authorKhujamatov, Halimjon
dc.contributor.authorDavronbekov, Dilmurod
dc.contributor.authorKhayrullaev, Alisher
dc.contributor.authorAbdullaev, Mirjamol
dc.contributor.authorMukhiddinov, Mukhriddin
dc.contributor.authorCho, Jinsoo
dc.contributor.otherDepartment of Data Communication Networks and Systems
dc.date.accessioned2024-12-16T16:27:42Z
dc.date.available2024-12-16T16:27:42Z
dc.date.issued2024
dc.departmentTashkent University of Information Technologiesen_US
dc.department-temp[Khujamatov, Halimjon; Cho, Jinsoo] Gachon Univ, Dept Comp Engn, Seongnam Si 1342, South Korea; [Davronbekov, Dilmurod; Khayrullaev, Alisher] Tashkent Univ Informat Technol, Dept Mobile Commun Technol, Tashkent 100200, Uzbekistan; [Abdullaev, Mirjamol] Tashkent State Univ Econ, Dept Informat Syst & Technol, Tashkent 100066, Uzbekistan; [Mukhiddinov, Mukhriddin] Univ Management & Future Technol, Dept Commun & Digital Technol, Tashkent 100208, Uzbekistanen_US
dc.descriptionKhujamatov, Halimjon/0000-0001-5206-635X; Khayrullaev, Alisher/0009-0005-5060-1079; Mukhiddinov, Mukhriddin/0000-0002-1424-0799; Davronbekov, Dilmurod/0000-0003-1193-7918; Mirjamol, Abdullayev/0000-0003-1664-7274en_US
dc.description.abstractResearchers have studied instances of power line technical failures, the significant rise in the energy loss index in the line connecting the distribution transformer and consumer meters, and the inability to control unauthorized line connections. New, innovative, and scientific approaches are required to address these issues while enhancing the reliability and efficiency of electricity supply. This study evaluates the reliability of Internet of Things (IoT)-aided remote monitoring systems specifically designed for a low-voltage overhead transmission line. Many methods of analysis and comparison have been employed to examine the reliability of wireless sensor devices used in real-time remote monitoring. A reliability model was developed to evaluate the reliability of the monitoring system in various situations. Based on the developed models, it was found that the reliability indicators of the proposed monitoring system were 98% in 1 month. In addition, it has been proven that the reliability of the system remains high even when an optional sensor in the network fails. This study investigates various IoT technologies, their integration into monitoring systems, and their effectiveness in enhancing the reliability and efficiency of electrical transmission infrastructure. The analysis includes data from field deployments, case studies, and simulations to assess performance metrics, such as accuracy, latency, and fault detection capabilities.en_US
dc.description.woscitationindexScience Citation Index Expanded
dc.identifier.citation0
dc.identifier.doi10.3390/s24185970
dc.identifier.issn1424-8220
dc.identifier.issue18en_US
dc.identifier.pmid39338715
dc.identifier.scopusqualityQ2
dc.identifier.urihttps://doi.org/10.3390/s24185970
dc.identifier.urihttps://tuit-demo.gcris.com/handle/123456789/45
dc.identifier.volume24en_US
dc.identifier.wosWOS:001322964300001
dc.identifier.wosqualityQ2
dc.institutionauthorKhujamatov, Halimjon
dc.language.isoenen_US
dc.publisherMdpien_US
dc.relation.publicationcategoryMakale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanıen_US
dc.rightsinfo:eu-repo/semantics/openAccessen_US
dc.subjectIoTen_US
dc.subjectremote monitoringen_US
dc.subjectlow-voltage transmission linesen_US
dc.subjectreliabilityen_US
dc.subjectfault detectionen_US
dc.subjectoverhead transmissionen_US
dc.titleErirms Evaluation of the Reliability of Iot-Aided Remote Monitoring Systems of Low-Voltage Overhead Transmission Linesen_US
dc.typeArticleen_US
dspace.entity.typePublication
relation.isAuthorOfPublicationd26bd0c5-0e7b-42d3-80b6-67e8c8fe0c1e
relation.isAuthorOfPublication.latestForDiscoveryd26bd0c5-0e7b-42d3-80b6-67e8c8fe0c1e
relation.isOrgUnitOfPublication32186c81-32e7-4d2d-bec5-80433ec7da5a
relation.isOrgUnitOfPublication.latestForDiscovery32186c81-32e7-4d2d-bec5-80433ec7da5a

Files